Bhoramdev Sahkari Shakkar Utpadak Karkhana - Chhattisgarh

39912684 supply, installation & testing of abt meter meter: abt meter, make : secure meter ltd., type : 3phase 4 wire, ctr200 / 5 5a amp, ct class 0.2 s, pt burden 30 va, apex : 100, with suitable standard modem and cable. note : all required parts will be arrange by contractor, competed test report are submitted ( as per approved vender of cspdcl / first class electrical contractor approved cspdcl ) supply, installation & testing of metering equipment, type : 3phase 4 wire, ctr 200 / 5 5a amp, ct class 0.2s, ct burden 7.5 va, ptr class : 0.2, ptr burden 30va, ( no of core : 02 dual core. ) note : all required parts will be arrange by contractor, completed test report are submitted. ( as per approved vender of cspdcl / first class electrical contractor approved cspdcl ) complete maintenance & overhauling of 7.5 mva transformers 01no. compete maintenance & overhauling of 3mva transformers 01no. ( with arrangement of filter machine, hydra seals and gaskets and consumables required for servicing activities ) complete maintenance of switchyard equipments ( pt, ct, vcb, isolator etc ) . supply & including painting of transformer, equipments structures, pole channel etc. with red oxide and aluminium paint as 33kv switchyard side only. supply and installation of 30 kv, 10 ka metal oxide surge arrestor 6 no. ( 3nos for installation 3 or 3 no for spares ) . supply and spreading gitti 40mm in switchyard. supply and installation of treated earth pit and connection with standard gi pipe and strip connection with equipment and in all respect as per is standard and specification 12 nos., supply & fixing dagnger caution board : 10 nos, complete testing of all switchyard quipment ( pt, ct, la transformer, feeder control room ) checking healthiness of interlocks and schemes of electrical protaction for smooth operation of plant submission of test report note : all required parts will be arrange by contractor, completed test report are submitted. ( as per approved vender of cspdcl / first class electrical contractor approved cspdcl ) supply & laying h.t. cable details: cci tropothen 12700 / 22000v 3x240sq / mm aluminium xlpe cable make havell / polycab supply and fixing of end termination kit note: all required parts will be arrange by contractor ( any contractor approved cspdcl ) rediator cleaning of copper tube & coper fins by new one in your existing cacw cooler ( radiators ) of 375 kw d.c. motor make kirlosker note : all tools & tackles, man power & required spares will be scope of contractor ( any contractor ) supply of new rtu unit ( panel ) for 6mw generation note: all required parts will be arrange by contractor, completed test report are submitted ( as per approved vender of cspdlc / first class electrical contractor approved cspdcl ) supply of new 6mw charger installation & testing opeating volt. 415, 3 phase 4wire, 50 hz ac float charger 110 123.75v / 60a, fcb charger, float mode 110 123.75v / 60a, boost mode 99 132v45a note: all required parts will be arrange by contractor, make uni insta battery charger / amarraja / as per is standard quality ( any contractor ) supply of new 7.5 kva transformer & 33 / 11 kv grid protection relay panel details : 67 / 67n.51 / 51n 3phase o / c & e / f realy, 78 vector surge relay, 81 freq relay, 87 transformer diff relay, 64r rest e / f relay, 63a axu. relay, 63b winding temp., 63c winding temp. act, 60 a p.t. failure relay, 86 master tube relay, 27 59 3 phase u / o volt. relay, 74 trip supervision relay, 50 / 51n idmt relay, 60 b p.t. failure relay, 21 distance protection relay, test terminal block, make l&t / abb / as per is standard quality ( any contractor approved cspdcl ) supply of new cacw cooler ( rediators ) of 3mw jyoti make alternator, capacity : 50kw, copper tube & copper fins note all required parts will by arrange by contractor ( any contractor ) supply of new excitation control pannel ( avr pannel ) ( instalation & testing ) generator : rating 6000kw, voltage 11000 volts frequency 50 hz phase 3 ph excitation : voltage 150 v dc current 5a dc note : all required parts will be arrange by contractor make sanilec / abb / l&t / as per is standard quality ( manufactures / authorised dealer ) supply of new excitation 6mw synchronous generator relay pannel ( instalation & testing ) for kw 6000, rpm 1500, pf 0.8 lag, statar volt. 11000, statar amp 394, insulation class f, phase 3, hz 50, connection star, ambient temp. 50ºc, inlet temp. 50ºc, exct. volt. 122, exct. amps 387, duty continious note : all required parts will be arrange by contractor make abb / l&t / as per is standard quality ( manufactures / authorised dealer ) factory boiler, make s.s. engineering, pune, capacity 70 m.t. per hr., working pre. 45kgs. per sq. cm. bank tube zone furnace walls 1. 70 tph boiler bank tube zone refractory work with material supply and construction. 2. construction of insulation wall with fire bricks total area 1300 square feet. ( approx ) 3. new insulation tiles fitting total area 1400 square feet. 4. all required material provided by contractor 5. having experience of 2 years of boiler refractory work....

Bhoramdev Sahkari Shakkar Utpadak Karkhana - Chhattisgarh

38197541 supply of items tender 06 ( authorised exprience contractor ) 1 rediator cleaning of copper tube & copper fins by new one in your existing cacw cooler ( radiators ) of 3mw jyoti make alternator note : all tools & tackles, man power & required spares will be scope of contractor ( any contractor ) 2 supply of new cacw cooler ( radiators ) of 3mw jyoti make alternator as per drawing no : 2ek 3178, capacity : 50kw, copper tube & copper fins ( any contractor ) 3 excitation control pannel ( avr pannel ) ( instalation & testing ) generator : rating 6000kw, voltage 11000 volts frequency 50 hz phase 3 ph excitation : voltage 150 v dc current 5a dc note : all required parts will be arrange by contractor make sanilec / abb / l&t ( manufactures / authorised dealer ) 4 6mw synchronous generator relay pannel ( instalation & testing ) for kw 6000, rpm 1500, pf 0.8 lag, statar volt. 11000, statar amp 394, insulation class f, phase 3, hz 50, connection star, ambient temp. 50ºc, inlet temp. 50ºc, exct. volt. 122, exct. amps 387, duty continious note : all required parts will be arrange by contractor make abb / l&t ( manufactures / authorised dealer ) 5 6mw bettery charger instalation & testing operating volt. 415, 3 phase 4wire, 50 hz ac float charger 110 123.75v / 60a, fcb charger float mode 110 123.75v / 60a, boost mode 99 132v / 45a note : all required parts will be arrange by contractor make uni insta battery charger / amarraja ( manufactures / authorised dealer ) 6 33kv / 11kv switch yeard maintenance & testing all c.t., p.t., l.a. & all control wirering testing, 7.5 mva & 2 mva transformer overhauling, ht to lt transformer testing, earthing strip replacement, all equipment ir testing note : all required parts will be arrange by contractor ( first class electrical contractor ) 7 cane carrier supply of ac vvvf drive along with 75 kw motor make siemens of suitable capacity type ie3, insulation class h, along with forced cooling arrangement. vvfd ( rating 90 kw ) should be supplied along with the following components. for incoming suitable mccb along with spreader terminal, rotary handle, all phase indications, multifunction meter, current transformer, heavy duty drive suitable for operation of motors. drive should be given in panel along with input choke, output choke, control mcb, led indications, push buttons, auxiliary contactors & signal isolator etc. the panel shall comprised of fan & filter, control transformer, power tb, control tb, door limit switch, panel shall comprise of hot air canopy, dust proof gasket & anti vibration pad. local control station with push button metering & indications as per site requirement. scope also include laying of cables incoming & out going 150 sq. mm, 3.5 core along with ( aproxmatly 40 mtr. ) copper cable all armoured, supply of 1.5 sq. mm, 16 core aluminium armoured cable ( aproxmatly 100 mtr. ) shall also be in the scope of party. scope of work includes supply, installation, testing & commissioning of system. note : all required parts will be arrange by contractor make abb / amtech ( manufactures / authorised dealer ) 8 digital process indicator model : 4c52000, input : 4 20 ma range i ) 0 to 600ºc ( 01 no. ) ii ) 200 to 200mmwc ( 01 no. ) iii ) 0 to 60 kg / cm² ( 01 no. ) iv ) 0 to 45 tph ( 02 nos. ) display : 4 digit, 1 red 7 segment led, transmitter supply : 24 vdc for power two wire transmitter supply : 90 to 270 vac / dc ( 45 65 hz ) mounting : flush on panel cutout : 138mm ( w ) x 68mm ( h ) note all range programmed with 4c52000 make nishko ( manufactures / authorised dealer ) 9 rediator cleaning of copper tube & coper fins by new one in your existing cacw cooler ( radiators ) of 375 kw d.c. motor make kirlosker note : all tools & tackles, man power & required spares will be scope of contractor ( any contractor ) 10 installation and testing abt meter detail : type 3 phase 4 wire, ctr 200 / 5a, ptr 33kv / 110v, class 0.2s, meter should be abt compatible make secure meters ltd. ( first class electrical contractor ) 11 installation and testing metering equipment detail : type 3 phase 4 wire, ctr 200 / 5 5a, ct class 0.2s, ct burden 7.5va, ptr 33kv / 110v, pt class 0.2, pt burden 30va, no of core 02 ( dual core ) ( first class electrical contractor ) 12 air compressure repairing & overhauling model eh 200, sl no. rec 000712, bore 215.9, strke 190, rpm 400, press 7.5, primemover k.w. 37, fad 4.08, spec no. 045.037, date jan 2011 ( including spares ) make kirloskar ( kirloskar, hall mark, khosla air compressor authorised service engineer experience must be produce similar work for five years ) 13 air compressure repairing & overhauling model 1ha2t, sl no. rec002866, l p bore 250, fad m³ / cm² 2135, h p bore 250 press kg / cm² 1, stroke 150, rpm 805, kw 37, spec.no. 296.140 make kirloskar pneumatic co. ltd. ( kirloskar, hall mark, khosla air compressor authorised service engineer experience must be produce similar work for five years ) 14 air compressure repairing & overhauling model eh 150, sl no. aa0054, bore 175.00, strke 165.00, rpm 660, press 7.50, primemover k.w., fad 4.08, spec no. 026001, date dec. 2011 ( including spares ) make kirloskar ( kirloskar, hall mark, khosla air compressor authorised service engineer experience must be produce similar work for five years ) 15 air compressure repairing & overhauling model tbtd mm, sr. no. al0367, lp bore 255, fad m³ / min. 6.29, stroke 120, rpm 650, speed no. 269121, make kirloskar pneumatir pvt. ltd. ( including spares ) make kirloskar ( kirloskar, hall mark, khosla air compressor authorised service engineer experience must be produce similar work for five years ) 16 air compressure repairing & overhauling model 65t, size 5&5 & 312x4, sr.no. 09112101 ( including spares ) make hall mark ( kirloskar, hall mark, khosla air compressor authorised service engineer experience must be produce similar work for five years ) 17 air compressure repairing & overhauling model ae 20, capacity 250cfm, pressure 12kg / cm², double cylinder ( including spares ) make khosla ( kirloskar, hall mark, khosla air compressor authorised service engineer experience must be produce similar work for five years ) 18 air blower repairing & overhauling w. p. 01 kg / cm², capacity 17.25m³ / min, motor 40 hp rpm 1000v belt drive with horizontal flow moc specification construction ci rotor pair s.g. iron costing body outer and other covers materials ci is 210 fe 260 gear pair alloy steel with hardend and craund bearing pair inside skf / zkl ( including spares ) make m.s. ankur ind. gujral ( oem / service engineer ) 19 dynamic balancing at factory site a. cane leveller 01no., b. fibrizer – 01no., c. bagasse cillo fan – 01no., d.id fan of 70mt boiler – 02 nos., e.fd fan of 70mt boiler – 02 nos., f.sa fan of 70mt boiler – 02 nos., g. pa fan of 70mt boiler – 01 no., h. id fan of 35mt boiler – 01 no., i. fd fan of 35mt boiler – 01 no., j. sa fan of 35mt boiler – 01 no., k. 3mw turbine – 02 nos., l. all c / f machine – 11 nos., ( five year experience of dynamic balancing in sugar factory ) 20 hydraulic accumulator of mills 9 nos. work pressure testing & refilling of n2 gas at factory site ( including spares ) note : spares should be from reputed mfg. make ( five year experience ) 21 complete repairing, replacement of spare parts & maintenance with belt conveyer repairing & new modification work of vacuum rotory filter. details of equipments make jard filtering area m² 76.83, size ( dia x l ) 12x24 ss screen hole size 625 micron make manufactures / authorised dealer ...

National Thermal Power Corporation Limited - Chhattisgarh

28822992 procurement of abt meters/special energy meters for ntpc dadri procurement of abt meters/special energy meters for national capitalpower station, dadri , abt mtr: 3ph/4w,57 277v,5a,cl:0.2+s/ware , abt mtr: 3ph/4w,57 277v,5a,cl:0.2+s/ware...

Nmdc Limited - Chhattisgarh

24698577 tender for civil and electrical erection work for installation of abt meter 220 kv mrs at nisp nagarnar...

Nmdc Limited - Chhattisgarh

23850071 tender for civil & electrical erection work for installation of abt meter 220 kv mrs at nisp nagarnai...